Example (demo data). Use only the details that match your own visit.
Short version (fits a line item)
Gas furnace maintenance. Replaced air filter, cleaned flame sensor, vacuumed and wiped out unit. Checked ignition, burners, safeties and venting. System operating normally at end of visit.
Full version (for the invoice notes or the service report)
Reason for visit: Seasonal gas furnace maintenance. Service performed: Replaced the air filter. Vacuumed and wiped out the unit. Cleaned the flame sensor. Inspected and cleaned the burners. System checks: Thermostat operation, ignition sequence, inducer motor, pressure switch and tubing, gas valve, rollout and high-limit safeties, venting and draft, and condensate drain checked. Temperature rise and gas pressure readings recorded in the service record. Recommendations: None today. The system was heating normally when we left.
Fill-in template
Gas furnace maintenance. [Work done: filter, cleaning, flame sensor, other]. Checked: [the items you actually checked]. Found: [anything that needs attention, or "no issues found"]. Recommended: [specific item] because [what you found]. Customer [approved / declined / will decide later].
What a furnace maintenance description should cover
The gas furnace checklist in Tech Gibberish has 24 items. You don't need all of them on the invoice, but the description should make clear which of these you actually checked:
- Air filter, thermostat operation, unit cleaning
- Burners, flame sensor, igniter and ignition sequence
- Inducer motor, pressure switch and tubing, gas valve, inlet and manifold gas pressure
- Combustion analysis and heat exchanger (only if you performed and recorded them)
- Blower compartment and airflow, electrical connections, control board
- Rollout and high-limit safeties, temperature rise
- High-efficiency condensate drain and trap, venting, flue and draft, carbon monoxide reading
See the full gas furnace maintenance checklist.
Keep these separate
- Checked vs. replaced. "Checked the igniter" and "replaced the igniter" are different jobs. Don't blur them.
- Recommendations need a reason. "Recommend replacing the inducer motor: it was noisy at startup and drawing high amps" is something a customer can act on. "Recommend inducer motor" is not.
- Record the customer's decision. Approved, declined or deferred, in plain words.
- No readings you didn't take. If you didn't run combustion analysis, leave it off.