AC
Tech’s note:
AC maint. Cleaned condenser coil, changed filter. Dual cap weak on herm side, replaced. Cooling good after.
Checklist taps:
- Air filter: Replaced
- Condenser coil / outdoor unit: Cleaned
- Capacitor: Replaced
- Cooling cycle / shutdown: Checked / OK
Customer report:
AC MAINTENANCE REPORT Reason for Visit We came out to do maintenance on your air conditioner. What We Did We cleaned the outdoor condenser coil and changed the air filter. We replaced the dual capacitor in the outdoor unit. Then we checked the cooling cycle and shutdown, and the system was cooling well afterward. What We Found The dual capacitor was weak on the compressor side. The capacitor gives the compressor the boost it needs to start and run, so a weak one can make it struggle to start. The new capacitor is in place. The condenser coil was dirty before we cleaned it. The cooling cycle and shutdown checked out fine. Going Forward Your condenser coil was dirty, and a dirty coil can't get rid of heat as well, so the unit runs longer to cool your home. A yearly cleaning will help keep it from building up again. Thank you for having us out today. Your air conditioner has a new capacitor and a clean coil, and it was cooling well when we finished. If you have any questions about this report, just give us a call. Example Tech
App screenshots taken November 18, 2026 with test data. Report not edited.
Heat pump
Tech’s note:
HP not heating well, outdoor coil iced. Defrost board bad, replaced. Ran defrost test, ok.
Checklist taps:
- Defrost board / sensor / termination: Replaced
- Heating mode operation: Checked / OK
Customer report:
HEAT PUMP SERVICE REPORT Reason for Visit Your heat pump was not heating well, and the outdoor coil was iced. What We Did We found the defrost board was bad and replaced it. We then ran a defrost test, which came out okay, and checked the heat pump's heating operation. What We Found The defrost board had gone bad. This board controls the heat pump's defrost cycle, which is how the unit clears ice from the outdoor coil in cold weather. With the new board in place, the defrost test was okay, and the heating operation checked out with no concerns. Thank you for having us out today. We're glad we could get the defrost board replaced and tested for you. If you have any questions about this report, just give us a call. Example Tech
App screenshots taken November 18, 2026 with test data. Report not edited.
Gas furnace
Tech’s note:
Furnace maintenance.
Checklist taps:
- Air filter: Checked / OK
- Flame sensor: Cleaned
- Ignition sequence / shutdown: Checked / OK
- Venting / flue / draft: Checked / OK
Customer report:
FURNACE MAINTENANCE REPORT Reason for Visit We came out to do maintenance on your furnace. What We Did We checked the air filter, the ignition sequence and shutdown, and the venting, flue and draft. We also cleaned the flame sensor. What We Found Everything we checked looked good. The air filter, the ignition sequence and shutdown, and the venting all checked out with no concerns. Thank you for having us out today. We're glad to report that everything we checked on your furnace looked good. If you have any questions about this report, just give us a call. Example Tech
App screenshots taken November 18, 2026 with test data. Report not edited.
Electric furnace
Tech’s note:
No heat upstairs. One heat strip open, replaced element and sequencer. All stages heating.
Checklist taps:
- Heat strips / elements: Replaced
- Sequencers / relays / contactors: Replaced
- Thermostat staging: Checked / OK
Customer report:
ELECTRIC FURNACE SERVICE REPORT Reason for Visit You were not getting heat upstairs. What We Did We replaced the heating element on one of the heat strips and replaced the sequencer, which turns the heat strips on in stages. We also checked the thermostat staging, and it looked good. After the work, we confirmed that all stages were heating. What We Found One of the heat strips in your electric furnace had an open element, which means it was no longer making heat. With the new element and sequencer in place, all stages of heat were working. Thank you for having us out today. We're glad we could get all of your heat working again. If you have any questions about this report, just give us a call. Example Tech
App screenshots taken November 18, 2026 with test data. Report not edited.
Boiler
Tech’s note:
Boiler annual. Bled air from upstairs rads, flushed LWCO. Pressure good. All zones heating.
Checklist taps:
- System pressure / water level: Checked / OK
- Low-water cutoff: Performed
- Air elimination: Performed
- Zone valves / controls: Checked / OK
Customer report:
BOILER MAINTENANCE REPORT Reason for Visit We came out to do annual maintenance on your boiler. What We Did We bled the air out of the upstairs radiators and flushed the low-water cutoff, which shuts the boiler down if the water level ever drops too low. We also tested the low-water cutoff, checked the air elimination, and checked the system pressure and water level and the zone valves and controls. What We Found Your boiler is in good shape. The system pressure and water level were good, the zone valves and controls checked out fine, and all zones were heating. Thank you for having us out today. We're glad to report your boiler and all of your zones are heating well. If you have any questions about this report, just give us a call. Example Tech
App screenshots taken November 18, 2026 with test data. Report not edited.
Oil furnace
Tech’s note:
Oil tune-up. New nozzle and filter, cleaned heat exchanger. Combustion test good.
Checklist taps:
- Oil nozzle: Replaced
- Oil filter: Replaced
- Heat exchanger / combustion chamber: Cleaned
- Smoke test / combustion analysis: Checked / OK
Customer report:
FURNACE MAINTENANCE REPORT Reason for Visit We came out to do a tune-up on your oil furnace. What We Did We replaced the oil nozzle and the oil filter, and we cleaned the heat exchanger and combustion chamber. We then ran a smoke test and combustion analysis. What We Found The smoke test and combustion analysis came back good, with no concerns. Going Forward Your furnace runs on oil, and oil equipment needs its nozzle and oil filter changed and the burner tuned every year to keep running cleanly. A yearly tune-up like today's will help keep your furnace burning cleanly. Thank you for having us out today. We're glad to report the combustion test came back good after the tune-up. If you have any questions about this report, just give us a call. Example Tech
App screenshots taken November 18, 2026 with test data. Report not edited.
General HVAC
Tech’s note:
Thermostat blank. Dead batteries, replaced, set schedule with customer.
Checklist taps:
- Thermostat operation: Checked / OK
Customer report:
HVAC SERVICE REPORT Reason for Visit We came out for a service call on your heating and cooling system. What We Did We replaced the dead batteries in your thermostat and set up its schedule with you. We then checked the thermostat's operation, and it had no concerns. What We Found Your thermostat screen was blank, and its batteries were dead. Recommendations 1. Replace the thermostat batteries about once a year, or whenever the low-battery icon shows, because a dead battery can shut off your heating or cooling. Thank you for having us out today. We're glad we could get your thermostat back up and set to your schedule. If you have any questions about this report, just give us a call. Example Tech
App screenshots taken November 18, 2026 with test data. Report not edited.