Example (demo data). Use only the details that match your own visit.
From the tech's note to the customer's report
Tech's note: "No heat upstairs. One heat strip open, replaced element and sequencer. All stages heating."
Customer report:
Reason for visit: You were not getting heat upstairs. What we found: One of the heat strips in your electric furnace had an open element, which means it was no longer making heat. What we did: Replaced the heating element and the sequencer, which turns the heat strips on in stages. Checked the thermostat staging. Result: After the repair, all stages were heating.
Short version, repair (fits a line item)
No heat upstairs. Found open heat strip element. Replaced element and sequencer. Checked thermostat staging. Verified all heat stages operating at end of visit.
Short version, maintenance (fits a line item)
Electric furnace maintenance. Replaced air filter, vacuumed and wiped out unit. Checked heat strips, amp draw, sequencers and relays, electrical connections, limit switches, temperature rise and fan delay. System heating normally at end of visit.
Fill-in template
[Complaint in the customer's words, or "Electric furnace maintenance"]. Found: [what you tested and the result]. Repaired: [part replaced or work done]. Checked: [the items you actually checked]. Verified: [stages heating / temperature rise / other] at end of visit. Recommended: [item] because [finding]. Customer [approved / declined / will decide later].
What an electric furnace report should cover
The electric furnace checklist in Tech Gibberish has 19 items, including:
- Air filter, thermostat operation, thermostat staging
- Heat strips and elements, heat strip amp draw
- Sequencers, relays and contactors
- Electrical connections and lugs, wiring heat damage
- Disconnect and line voltage, breakers and fuses, control board
- Limit switches and thermal safeties
- Blower wheel and airflow, temperature rise, fan delay operation
See the full electric furnace maintenance checklist.
Keep these separate
- Name the stage. "One heat strip element was open" tells the customer more than "heater bad."
- Say how you verified it. "All stages heating" is the proof the repair worked.
- Wiring findings get the detail. If you saw heat damage on wiring or a lug, describe what you saw and what you did about it.
- Recommendations need a reason, and the customer's decision goes in writing.