Example (demo data). Use only the details that match your own visit.
Short version, repair call (fits a line item)
No-cool service call. Outdoor unit not running. Run capacitor tested failed. Replaced run capacitor. Verified compressor and outdoor fan startup and cooling operation.
Short version, found during maintenance (fits a line item)
AC maintenance. Dual capacitor tested weak on the compressor side. Replaced dual capacitor. Verified cooling cycle and shutdown. System cooling well at end of visit.
Full version (for the invoice notes or the service report)
Reason for visit: Air conditioner maintenance. What we found: The dual capacitor was weak on the compressor side. The capacitor gives the compressor the boost it needs to start and run, so a weak one can make it struggle to start. Service performed: Replaced the dual capacitor. Cleaned the condenser coil and changed the air filter. System checks: Checked the cooling cycle and shutdown after the replacement. Readings recorded in the service record. Result: The system was cooling well at the end of the visit.
Fill-in template
[Reason for visit: complaint or maintenance]. Found: [capacitor type] tested [failed / below its rated value] [on which side, if dual]. Replaced: [capacitor type]. Verified: [compressor and fan startup / amps / cooling or heating operation] after the replacement. Customer [approved the repair / was informed before the repair].
Repair or recommendation?
- Failed and the system wasn't running: that's a repair. Write it as found, replaced, verified.
- Tested below its rating but still working: that's a finding. Give the customer the reading-based reason and let them decide. For example: "The capacitor tested lower than its rated value. It is still working. We recommend replacing it, since it tested below its rating. Customer will decide after reviewing the quote."
- Either way, write down what the customer decided.
What to check and mention
These come from the AC and heat pump checklists in Tech Gibberish. Mention the ones you actually checked:
- Capacitor
- Contactor / relay
- Compressor amps
- Outdoor fan motor / blade
- Electrical connections, disconnect / line voltage
- Cooling cycle / shutdown (and heating mode operation on a heat pump)
See the full AC maintenance checklist and heat pump maintenance checklist.
Keep these separate
- Tested vs. assumed. "Tested failed" or "tested below its rating" beats "bad cap." Put the reading in the service record.
- Replaced vs. checked. If the contactor tested fine, write "checked," not "serviced."
- Today's repair vs. future recommendations. Keep them in separate lines.